EKO Line boilers provide a convenient, safe and environmentally friendly way to heat your home and domestic hot water with wood. EKO boilers assure the independence and self-reliance that heating with wood provides.
Because the boilers use wood gasification combustion, they give unusually high overall heating efficiency. They use substantially less wood than conventional boilers and outdoor water stoves with no visible smoke when fully operating.
EKO boilers burn so clean, they are safer (virtually no risk of a chimney fire) and result in cleaner air for everyone. They also help to substantially reduce greenhouse gas emissions. EKO Line boilers enable you to increase the warm security of your home in a safe, environmentally responsible way.
UL/CSA Approved by OMNI
WATCH VIDEO CLIP OF EKO LINE BOILER COMBUSTION
(:30 sec, 1.7M, .wmv format)
Downloads:
Eko Brochure
Eko Manual
Eko Label
Eko Test Protocol
Eko Certificate
Controller Manual
Boiler construction - elements
Boiler Output |
Chimney Section |
95k btu
|
8 inches
|
135k btu
|
8 inches
|
205k btu
|
8.25 inches
|
275k btu
|
8.25 inches
|
- Sealed wood gasification chamber - used simultaneously as a loading chamber. When appropriate amount of primary air supplied by the pressure fan is delivered, wood gas is generated
- Nozzle - made of refractory concrete, mixes wood gases with the secondary air and a flammable mixture is produced that undergoes self-ignition at about 1000°F
- Exhaust reheat space - the main combustion chamber, where temperature reaches about 2000°F serves as an ash pit
- Smoke tube heat exchanger - (flue gas to water) heats up the installation water
- Fan - linked to the microchip controller, monitoring the quality of the whole burning process
- Safe guard thermostat - each boiler is equipped with an additional safe guard thermostat, which switches off the fan while the water gets up to 180°F
Boiler construction - materials
- Boiler body - boiler casing is made of welded metal sheets that are 6mm thick, whereas the remaining walls are 4mm thick.
- Heat exchanger - smoke tube heat exchanger made of tube with dimensions 57 x 4mm
- Insulation - boiler thermal insulation is composed of glass wool of Nobasil 20mm thick, while the i external casing consists of metal sheet panels 0.8mm thick (powder painted)
- Nozzle - ceramic element made of refractory concrete (working temp. up to 2100° F)
- Chimney flap - made of high quality steel. Tight flap adhesion to the combustion duct assures the burning chamber tightness
- Boiler regulator - placed on upper boiler cover. The regulator is fixed to the boiler cover by stuck catch
- Chimney flue - made of 4mm steel tube
- Ash pit - steel bottom of the burning chamber, ceramic ash pit added (working temp. 2100° F) and additionally covered by refractory concrete
- Boiler door - produced of high quality steel, insulated with Nobasil thermal insulation and inside covered by refractory concrete layer.
Also protected with heat-resisting fiberglass cord.
Boiler sizeing
EKO-Line boilers may be used for heating any kind of building. They are mostly used in one-family houses, drying houses, workshops, halls, or greenhouses. However, boiler placement is not limited to these applications; the above are just examples of where EKO-Line boilers have worked with success.
Selecting a boiler that adequately fits ones output is very important. An improperly chosen boiler may subject the end-user to unnecessary expenses during boiler usage.
Boiler output should be based on a building’s heat demand, calculated by a qualified central heating designer. To select the appropriate boiler, the a/m calculated value should be increased by 20%. If this calculation isn't performed, boiler sizing may be chosen using the heat factor in relation to m3 of building cubature. Heat factor values should be determined as 30-50 W/m3 depending on heat insulation.
The scheme is only an example and New Horizon is not responsible for the wrong boiler choice.
Technical Data for EKO-Line Boilers
Parameters
|
Unit
|
EKO-Line
25
|
EKO-Line
40
|
EKO-Line
60
|
EKO-Line
80
|
Power range
|
kBtu
|
85
|
137
|
205
|
275
|
Weight
|
Lb
|
1280
|
1390
|
2070
|
2712
|
Height
|
A inch
|
51.5
|
59
|
60.5
|
60.5
|
Height of heating water exit
|
B inch
|
48.5
|
56
|
56.5
|
56.5
|
Height of heating water entry
|
C inch
|
8.3
|
6.0
|
7.9
|
7.9
|
Height of outlet valve
|
D inch
|
5.1
|
2.7
|
5.1
|
5.1
|
Height of chimney flue
|
E inch
|
37.4
|
50.0
|
45.7
|
45.7
|
Width including handle
|
F inch
|
24.8
|
24.8
|
30.3
|
30.3
|
Width including casing
|
G inch
|
23.6
|
23.6
|
29.1
|
29.1
|
Depth
|
H inch
|
41.1
|
41.1
|
53.5
|
52.7
|
Hot water exit
|
I inch
|
12.6
|
12.6
|
24.0
|
24.0
|
Diameter of chimney flue
|
J inch
|
7.8
|
7.8
|
8.2
|
8.2
|
Diameter of hot water exit
|
inch
|
2.0
|
2.0
|
2.5
|
2.5
|
Diameter of hot water entry
|
inch
|
2.0
|
2.0
|
2.5
|
2.5
|
Kind of connection
|
-
|
thread
|
thread
|
flange
|
flange
|
Diameter of drain valve
|
inch
|
0.5
|
0.5
|
0.5
|
0.5
|
Water capacity
|
Gal
|
20
|
25
|
47
|
54
|
Volume of loading chamber (gasification)
|
Gal
|
31
|
49
|
82
|
123
|
Power consumption
|
W
|
50
|
50
|
100
|
100
|
Moisture of wood:
|
- recommended
|
%
|
15 - 25
|
- acceptable
|
%
|
10 - 35
|
Maximum log diameter
|
inch
|
7
|
7
|
7
|
7
|
Maximum length of logs
|
inch
|
23
|
23
|
28
|
38
|
Average flue gas temperature
|
F
|
340
|
Max. w orking pressure
|
PSI
|
25
|
Required chimney draught
|
Pa
|
15 - 20
|
Voltage / frequency
|
V/Hz
|
120V/60Hz
|
RK 2001 UA Regulator
EKO-Line boilers are equipped with
RK 2001 UA enabling:
- Interaction with circulating pump,
- Interaction with room temperature sensor, installed in the room and connected with the boiler regulator by two-strand wire
Modulation of fan rotation,
- Boiler output adapting to actual weather conditions,
- Interaction with EUROSTER room thermostat
Each boiler is able to work without room temperature sensor as well.
Basing information about boiler assembly
1. Boiler placing. Boiler can be placed in the heating room, basement, or in an outside wood storage building. There should be enough space to accommodate fuel storage for the whole heating season.
2. Boiler start-up rules. Each boiler should be connected to the heating system of which the heating capacity equals that of the boiler output.
To protect the boiler against low-temperature corrosion the end-user should assure return temperature does
not reach lower than 120F. It is possible by installing of four way mixing valve.
Boiler has to be connected to the chimney duct in the smallest distance possible.
Chimney duct should be insulated to prevent condensation (low exhaust temperature).
The chimney should have the section and height assuring required chimney draught (see table).