ATTACK SLX from the 7000 series is a wood biomass boiler with a professional solution for the most demanding customers who demand the highest quality, savings and emphasis on the environment. It has won a number of awards and impresses with his high-quality construction, high efficiency and oversized loading chamber. In the LAMBDA Touch version, it is possible to connect to the Internet and control it remotely via a cell phone.


SLX wood gasifying boiler which has an oversized feeding chamber with a long time of burning Reducing time by more than 50%. The ATTACK SLX biomass boiler is equipped with an oversized feeding chamber (60 gal.) with a length (28 " and 32.2 ").


Long burning
With full use of the capacity of the chamber you can do other activities 8 to 12 hours. Continuous burning for one fuel load (applies only to continuous operation). The advantage of the oversized loading space is the division of wood at the meter which is sufficient to divide only once.


Models 30SLX, 40SLX, 55SLX

DOWNLOADS:
Technical Manual (pdf)
User Manual (pdf)


VIDEOS:

Attack SLX Instruction Video



Attack Model Comparison

 

Attack SLX Chimney Connection




Technical Specifications:

Parameter Unit SLX30 SLX40 SLX55
Nominal output of the boiler kW 30 40 55
Output range kW 15 – 30 20 – 40 27.5 – 55
Area of the exchanger   3.32
Volume of the feeding chamber dm³   230
Dimensions of the feeding hole mm  
Prescribed chimney draught Pa  
Prescribed chimney draught mbar  
Max. working overpressure of the water kPa  
Pressure loss of the water (ΔT 10K) kPa 2.4 3.9 6.1
Pressure loss of the water (ΔT 20K) kPa 1.2 1.9 3.2
Weight of the boiler kg   650
Diameter of the flue gas outlet mm  
Height of the boiler mm  
Width of the boiler mm  
Depth of the boiler mm   1506
Depth of the feeding chamber mm   790
Diameter of the riser pipe “E”   G 2″
Diameter of the reverse “F”   G 2″
Protection class IP  
Electrical input at the nominal output W   78
Electrical input at the minimal output W   52
Electrical input at the standby mode W  
Boiler efficiency % 90.3 90.4 90.3
Boiler class  
Temperature of the flue gas by the nominal output °C 175 165 180
Temperature of the flue gas by the minimal output °C 140 135 145
Mass flow of the flue gas by the nominal output kg/s 0.21 0.027 0.033
Mass flow of the flue gas by the minimal output kg/s 0.014 0.017 0.023
Max. noise level dB  
Class and type of the fuel  
Average wood consumption kg/h 7.8 10.4 14.3
Indicative consumption of the wood per season  
Max. length of logs mm   750
Time of burning by nominal output * h 6.5 6 4
Volume of the water in the boiler l   136
Recommended volume of the accumulation tank l   2500 – 3500
Voltage V/Hz  
Range of the setting the temperature of the heating water °C  
Capacity of the contacts of the boiler regulator (PROFI version)  

 